Accéder directement au contenu

David Sarrut

David Sarrut
18
Documents

Présentation

See: [PubMed](http://www.ncbi.nlm.nih.gov/pubmed/?term=Sarrut+D) See: [Google Scholar profile](https://scholar.google.fr/citations?user=Ugm1VFsAAAAJ&hl=en) and [my web page](http://dsarrut.github.io) (just ask if you need pdf)

Publications

nicolas-freud

An empirical model for calculation of the collimator contamination dose in therapeutic proton beams

M. Vidal , L. de Marzi , H. Szymanowski , L. Guinement , C. Nauraye
Physics in Medicine and Biology, 2016, 61, pp.1532-1545. ⟨10.1088/0031-9155/61/4/1532⟩
Article dans une revue hal-01272853v1

Monte Carlo simulation of prompt gamma-ray emission in proton therapy using a specific track length estimator

W. El Kanawati , J.M. Letang , D. Dauvergne , M. Pinto , D. Sarrut
Physics in Medicine and Biology, 2015, 60 (20), pp.8067. ⟨10.1088/0031-9155/60/20/8067⟩
Article dans une revue hal-01207342v1

A track length estimator method for dose calculations in low-energy x-ray irradiations: implementation, properties and performance

F. Baldacci , A. Mittone , A. Bravin , P. Coan , F. Delaire
Zeitschrift fur Medizinische Physik, 2015, 25 (1), pp.36-47. ⟨10.1016/j.zemedi.2014.04.001⟩
Article dans une revue hal-01015846v1

Split exponential track length estimator for Monte-Carlo simulations of small-animal radiation therapy

F Smekens , J M Létang , C Noblet , S Chiavassa , G Delpon
Physics in Medicine and Biology, 2014, 59 (24), pp.7703-7715. ⟨10.1088/0031-9155/59/24/7703⟩
Article dans une revue hal-01124424v1
Image document

A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications

D. Sarrut , M. Bardiès , N. Boussion , N. Freud , S. Jan
Medical Physics, 2014, 41, pp.064301. ⟨10.1118/1.4871617⟩
Article dans une revue hal-01015819v1

Filtered backprojection proton CT reconstruction along most likely paths

S. Rit , G. Dedes , N. Freud , D. Sarrut , J.-M. Letang
Medical Physics, 2013, 40 (3), pp.031103. ⟨10.1118/1.4789589⟩
Article dans une revue hal-00796949v1

Machine learning-based patient specific prompt-gamma dose monitoring in proton therapy

P. Gueth , D. Dauvergne , N. Freud , Jean Michel Létang , C. Ray
Physics in Medicine and Biology, 2013, 58 (13), pp.4563. ⟨10.1088/0031-9155/58/13/4563⟩
Article dans une revue hal-00849321v1

An efficient numerical tool for dose deposition prediction applied to synchrotron medical imaging and radiation therapy

A. Mittone , F. Baldacci , A. Bravin , E. Brun , E. Delaire
Journal of Synchrotron Radiation, 2013, 20 (5), pp.785-92. ⟨10.1107/S0909049513017184⟩
Article dans une revue hal-00849320v1

GATE as a GEANT4-based Monte Carlo platform for the evaluation of proton pencil beam scanning treatment plans

L. Grevillot , D. Bertrand , F. Dessy , N. Freud , D. Sarrut
Physics in Medicine and Biology, 2012, 57 (13), pp.4223. ⟨10.1088/0031-9155/57/13/4223⟩
Article dans une revue hal-00797063v1

A Monte Carlo pencil beam scanning model for proton treatment plan simulation using GATE/GEANT4.

L. Grevillot , D. Bertrand , F. Dessy , N. Freud , D. Sarrut
Physics in Medicine and Biology, 2011, 56 (16), pp.5203-19. ⟨10.1088/0031-9155/56/16/008⟩
Article dans une revue hal-00630709v1

Monte Carlo simulation of prompt-γ emission in proton therapy using a track length estimator

J.M. Letang , W. El Kanawati , D. Dauvergne , M. Pinto , D. Sarrut
ICTR-PHE 2016, Feb 2016, Genève, Switzerland
Communication dans un congrès hal-01276435v1

Simulation of x-ray images from the planning CT for online correction of scatter in cone-beam CT

S. Rit , E. Romero , M. Vila Oliva , S. Brousmiche , D. Sarrut
ESTRO 33, Apr 2014, Vienne, Austria. pp.PO-0921
Communication dans un congrès hal-01053241v1

Machine-learning-based patient specific prompt-gamma dose monitoring in protontherapy

P. Gueth , D. Dauvergne , N. Freud , J.-M. Létang , C. Ray
52nd Annual Conference of the Particle Therapy Co-Operative Group, Jun 2013, Essen, Germany
Communication dans un congrès hal-00838405v1

Distance-driven binning for proton CT filtered backprojection along most likely paths

S. Rit , N. Freud , D. Sarrut , J.-M. Letang
Second International Conference on Image Formation in X-Ray Computed Tomography, Jun 2012, Salt Lake City, United States. pp.382
Communication dans un congrès hal-00829634v1
Image document

Gate simulation of a complete proton treatment combined with prompt-gamma monitoring

P. Gueth , L. Grevillot , D. Dauvergne , N. Freud , J.-M. Létang
2012 Nuclear Science Symposium, Medical Imaging Conference, Oct 2012, Anaheim, United States
Communication dans un congrès hal-00838620v1

ThIS : A Geant4-based Therapeutic Irradiation Simulator

L. Guigues , D. Sarrut , N. Dufour , M.C. Ricol , E. Testa
1st European Workshop on Monte Carlo Treatment Planning (MCTP), 2006, Gent, Belgium
Communication dans un congrès hal-01921002v1

A Platform for Monte Carlo Simulation of Cancer Therapy with Photon and Light Ions Beams based on the Geant 4 Toolkit

L. Guigues , D. Sarrut , N. Dufour , M.C. Ricol , E. Testa
IEEE Nuclear Sciences Symposium, 2006, San Diego, USA, Unknown Region
Communication dans un congrès hal-01921001v1