
Voichita Maxim
73
Documents
Publications
Publications
|
A convergent Plug-and-Play Majorization-Minimization algorithm for Poisson inverse problems2025
Preprints, Working Papers, ...
hal-04968919
v1
|
|
Tomographic reconstruction from Poisson distributed data: a fast and convergent EM-TV dual approach2018
Preprints, Working Papers, ...
hal-01892281
v1
|
|
Fast deconvolution using a combination of Richardson-Lucy iterations and diffusion regularization32nd European Signal Processing Conference (EUSIPCO), EURASIP, Aug 2024, Lyon, France. ⟨10.23919/eusipco63174.2024.10715053⟩
Conference papers
hal-04693188
v1
|
|
Reconstruction tomographique faible dose en imagerie dentaire : régularisation TV versus UNetXXVIIIème Colloque Francophone de Traitement du Signal et des Images (Gretsi 2022), Sep 2022, Nancy, France
Conference papers
hal-03706225
v1
|
|
Combining conditional GAN with VGG perceptual loss for bones CT image reconstruction16th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine (Fully3D), Jul 2021, Leuven, Belgium
Conference papers
hal-03706167
v1
|
Efficiency of TV-regularized algorithms in computed tomography with Poisson-Gaussian noise2020 28th European Signal Processing Conference (EUSIPCO), Jan 2021, Amsterdam, Netherlands. pp.1294-1298, ⟨10.23919/Eusipco47968.2020.9287762⟩
Conference papers
hal-03447989
v1
|
|
Dual approach for TV-regularized Maximum Likelihood Expectation Maximization in tomography with Poisson dataICIAM, Jul 2019, Valencia, Spain
Conference papers
hal-02359496
v1
|
|
Challenges in Compton camera imaging for medical applicationsModern Challenges in Imaging, In the Footsteps of Allan MacLeod Cormack, Aug 2019, Tufts University, United States
Conference papers
hal-02359478
v1
|
|
Very Fast Acquisition of Tilt series in Environmental TEM Tomography: Tips and TricksXVIème colloque de la Société Française des Microscopies, Société Française des Microscopies (SFµ), Jul 2019, Poitiers, France
Conference papers
hal-02378507
v1
|
|
A maximum-a-posteriori EM reconstruction method based on total variation regularization for Compton camera imaging58th Annual Conference of The Particle Therapy Co-Operative Group (PTCOG58), Jun 2019, Manchester, United Kingdom
Conference papers
hal-02359539
v1
|
|
Total variation regularization in tomography with Poisson distributed dataApplied Inverse Problems (AIP), Jul 2019, Grenoble, France
Conference papers
hal-02359404
v1
|
|
An extension of the GATE Monte Carlo simulation toolkit to model Compton Camera systemsThird Geant4 International User Conference, Oct 2018, Bordeaux, France
Conference papers
hal-01926614
v1
|
|
|
Total variation and point spread function priors for MLEM reconstruction in Compton camera imaging2018 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Nov 2018, Sydney, Australia. ⟨10.1109/NSSMIC.2018.8824767⟩
Conference papers
hal-02359265
v1
|
Practical considerations for Compton camera analytic image reconstructionThe 9th International Conference ”Inverse Problems: Modeling and Simulation” (IPMS-2018), May 2018, Malta, Malta
Conference papers
hal-02359645
v1
|
|
Compton camera imaging and Radon transforms on the cone: From data to images100 Years of the Radon Transform, Mar 2017, Linz, Austria
Conference papers
hal-02359629
v1
|
|
Versatile Compton camera for high energy gamma rays: Monte Carlo comparison with Anger camera for medical imaging2nd Jagiellonan Symposium on Fundamental and Applied Subatomic Physics, Jun 2017, Krakow, Poland. pp.1639-1645, ⟨10.5506/APhysPolB.48.1639⟩
Conference papers
hal-01609541
v1
|
|
|
Environmental Transmission Electron Tomography: fast 3D analysis of nano-materialsEuropean Microscopy Congress, Aug 2016, Lyon, France. pp.29-30, ⟨10.1002/9783527808465.EMC2016.6438⟩
Conference papers
hal-01871240
v1
|
Online control of the beam range during HadrontherapyForum de la recherche en cancérologie Rhône-Alpes Auvergne, Apr 2015, Lyon, France
Conference papers
hal-01241411
v1
|
|
Development of a Compton Camera for medical applications based on SSD and scintillation detectorsNDIP'2014, 7th International Conference on New Developments in Photodetection, Jun 2014, Tours, France
Conference papers
in2p3-01071940
v1
|
|
Compton imaging in proton therapy: reconstructed image of the simulated prompt-γ distributionICTR-PHE 2014, Feb 2014, Genève, Switzerland. pp.S43
Conference papers
hal-01052717
v1
|
|
Data models for the Compton camera acquisition and their influence on the reconstructed imagesICTR-PHE 2014, Feb 2014, Genève, Switzerland. pp.S66
Conference papers
hal-01052724
v1
|
|
Online control of the beam range during Hadrontherapy: a review9ème journée du CLARA, Jun 2014, Lyon, France
Conference papers
hal-01054193
v1
|
|
Compton imaging of prompt-gamma radiation in proton therapy: influence of the attenuation in the volume and of the detector performances9ème journée scientifique du CLARA, Jun 2014, Lyon, France
Conference papers
hal-01054191
v1
|
|
Compton imaging in proton beam therapy: from GATE simulations to image reconstructionInterdisciplinary Symposium on Signals and Systems for Medical Applications, Jun 2013, Paris, France
Conference papers
hal-00850519
v1
|
|
Tomographic reconstruction for Compton imaging in proton beam therapyWorkshop "The future of radiation oncology : Imaging, Dosimetry, Biology & Therapy", Sep 2013, Berder Island, France
Conference papers
hal-00872790
v1
|
|
|
Real-Time Online Monitoring of the Ion Range by Means of Prompt Secondary Radiations3rd International Conference On Advancements In Nuclear Instrumentation Measurement Methods And Their Applications (ANIMMA 2013), Jun 2013, Marseille, France. pp.1-8, ⟨10.1109/ANIMMA.2013.6728046⟩
Conference papers
hal-00873701
v1
|
Imagerie Compton en protonthérapie : de la simulation GATE à la reconstruction d'imagesXXIVème Colloque GRETSI - Traitement du Signal et des Images (GRETSI'13), Sep 2013, Brest, France
Conference papers
hal-00850529
v1
|
|
Image reconstruction for the Compton camera: calculation of the system matrixInterdisciplinary Symposium on Signals and Systems for Medical Applications, Jun 2013, Paris, France
Conference papers
hal-00850525
v1
|
|
Monitoring the Bragg peak during ion therapy by means of prompt radiation. The ENVISION program52nd Annual Conference of the Particle Therapy Co-Operative Group, Jun 2013, Essen, Germany
Conference papers
hal-00838430
v1
|
|
Reconstruction tomographique pour l'imagerie SPECT avec une caméra ComptonXIème Colloque Franco-Roumain de Mathématiques Appliquées, Aug 2012, Bucarest, Roumanie. pp.74
Conference papers
hal-00871681
v1
|
|
Algorithmes LM-MLEM pour la reconstruction d'images pour caméra ComptonNouvelles méthodologies en imagerie du vivant, Dec 2012, Lyon, France
Conference papers
hal-00828881
v1
|
|
Image reconstruction for Compton camera applied to 3D prompt imaging during ion beam therapyIEEE Nuclear Science Symposium and Medical Imaging Conference, 2011, Valencia, Spain. pp.3518 - 3521, ⟨10.1109/NSSMIC.2011.6152647⟩
Conference papers
hal-01920979
v1
|
|
Imaging system for QA: present status and future prospects2nd NIRS-ETOILE symposium, Nov 2011, Lyon, France
Conference papers
in2p3-00715886
v1
|
|
Imaging System for QI: Present Status and Future Prospects2nd NIRS-ETOILE Joint Symposium on Carbon Ion Therapy, Nov 2011, Lyon, France
Conference papers
in2p3-00773070
v1
|
Reconstruction tomographique et déconvolution aveugle en TEP : une méthode d’apprentissage profond hybrideXXVIIIème Colloque Francophone de Traitement du Signal et des Images (Gretsi 2022), Sep 2022, Nancy, France
Conference poster
hal-03706239
v1
|
|
|
Comparison of efficiency and activity recovery coefficients of Compton and Anger cameras in Nuclear MedicineIEEE Nuclear Science Symposium and Medical Imaging Conference (IEEE NSS MIC) 2021, Oct 2021, Virtual Yokohama, Japan, Oct 2021, Yokohama (virtual), Japan
Conference poster
hal-03473005
v1
|
Comparison between Anger and Compton cameras for medical imaging: A Monte Carlo simulation studyForum de la Recherche en Cancérologie Auvergne-Rhône-Alpes, Apr 2017, Villeurbanne, France.
Conference poster
in2p3-01501686
v1
|
|
Comparison between Anger and Compton cameras for medical imaging: a Monte Carlo simulation study2017 IEEE NSS/MIC/RTSD, Oct 2017, Atlanta, United States. 2017
Conference poster
hal-01609932
v1
|
|
Comparison between Anger and Compton cameras for medical imaging: a Monte Carlo simulation study56èmes Journées Scientifiques de la SFPM, Jun 2017, Lyon, France. 2017
Conference poster
hal-01609928
v1
|
|
Time-of-Flight Collimated- and Compton-Cameras Development for Ion Beam Therapy MonitoringForum de la recherche en cancérologie Rhône-Alpes Auvergne, Mar 2016, Lyon, France
Conference poster
hal-01297637
v1
|
|
|
Development of a Time-Of-Flight Compton Camera for Online Control of Ion therapyICTR-PHE 2014, Feb 2014, Genève, Switzerland
Conference poster
hal-00945490
v1
|
|
DEVELOPMENT OF COMPTON CAMERA PROTOTYPE FOR HADRONTHERAPY MONITORING AND MEDICAL IMAGINGFirst International Summer School on Intelligent Front-End Signal Processing for Frontier Exploitation in Research and Industry, Jul 2013, Oxford, United Kingdom
Conference poster
hal-01922290
v1
|
|
Reconstruction tomographique et application en imagerie caméra Compton et en microscopie électroniqueTraitement du signal et de l'image [eess.SP]. Institut National des Sciences Appliquées de Lyon, 2019
Habilitation à diriger des recherches
tel-02946771
v1
|
|
Image deconvolution for fast Tomography in Environmental Transmission Electron MicroscopyWiley-VCH Verlag GmbH & Co. KGaA, pp.101 - 102, 2016, 9783527808465. ⟨10.1002/9783527808465.EMC2016.6973⟩
Books
hal-01871239
v1
|
|
2012 Activity Report of the Regional Research Programme on Hadrontherapy for the ETOILE Center[Research Report] Centre Etoile; Université Lyon 1 - Claude Bernard. 2013
Reports
(Research report)
hal-00840163
v1
|
|
Restauration de signaux bruités observés sur des plans d'expérience aléatoiresMathématiques [math]. Université Joseph-Fourier - Grenoble I, 2003. Français. ⟨NNT : ⟩
Theses
tel-00005298
v1
|
|
Restauration de signaux bruités observés sur des plans d'expérience aléatoiresInterface homme-machine [cs.HC]. Institut National Polytechnique de Grenoble - INPG, 2003. Français. ⟨NNT : ⟩
Theses
tel-00004375
v1
|
Loading...
Loading...